        CP series low frequency online UPS 10 ~ 600kVA

        Product profile

        The CP series UPS has high reliability, anti-interference ability, high fault tolerance, lightning protection, high surge resistance, strong overload capacity and other characteristics. The rated capacity ranges from 10 to 600kVA. This series of products can be used in parallel, hot backup or standalone, and is suitable for data centers in banks, securities and other institutions, as well as industries such as communication, transportation and power, and industrial automation.


        Basic Features

        ● Double conversion true online design, using digital technology UPS with perfect protection function and high reliability;

        1.The inverter adopts the full digital vector control technology of dual DSP, MCU and DDC real-time processing,?

        to accurately control the parameters of the 1747208778184787.jpgmachine and conduct comprehensive control over it.

        2.Advanced IGBT high-frequency pulse width modulation technology (PWM) is combined to reduce system noise?

        and power loss, and ensure that customers can obtain high quality voltage output and the highest benefit in?

        various working load states.

        3.Double conversion, pure online sine wave output, no matter in the mains mode or battery mode, can output

        low distortion pure sine wave power supply, to provide the best power supply guarantee for the user's load?

        equipment.

        4.Output belt isolation transformer to ensure the full isolation of load and public power grid. The machine?

        equipped with isolation transformer will not appear DC components in the load, can effectively protect the?

        computer, the switching power supply of network and communication equipment is not damaged by DC?

        current, at the same time, for the nonlinear load, can also show excellent dynamic performance, improve?

        the load capacity of the machine, and the load compatibility is good.

        5.Automatic frequency / phase synchronization function to avoid the impact of input frequency hopping on the device.

        6.Perfect protection function, with AC input overvoltage, low voltage protection, output overvoltage low voltage protection, output overload short circuit protection, battery low voltage warning protection, overtemperature protection, so as to greatly ensure the stability and reliability of the system operation.

        7.The use of high-power IGBT devices makes the inverter have a strong overload capacity and impact resistance, and enhances the adaptability to the power grid.

        8.Intelligent speed regulating fan, low noise and energy saving

        9.Chinese and English LCD operation interface, more convenient management.

        ● Flexible parallel machine technology is suitable for different loads of the system single machine, 1+1 parallel machine, N+1 parallel machine operation;

        Make the parallel UPS in a relatively independent working state, intelligently, quickly and accurately to the best (phase difference<0.50), dynamic implementation of the load active and reactive power, and realize the precise load evenly, from the fault UPS system accurately and reliably, ensure that the parallel system continues to provide high quality ac power supply, the parallel system UPS circulation is almost zero, the current imbalance is less than 2%.

        Multi-machine parallel system: allows users to realize parallel operation of up to eight UPS in key applications. Advanced monitoring and high DSP digital control technology make the parallel system as simple as single machine. All UPS are equal, and there is no master-slave relationship, which is real equality. If you buy a single such UPS, you can easily expand to a "1 + 1" dual parallel machine when you need to expand or improve your reliability, or continue to expand to an N + X multi-machine redundancy system.

        ● The parallel machine can share the battery pack

        Greatly convenient for users to use, and for users to save costs.

        ● Intelligent battery management mode

        The intelligent battery charge and discharge mode and management mode can effectively improve the battery life, and matching the corresponding components can accurately calculate the battery discharge time, convenient for user management.

        ● The system has undergone strict short circuit test and 2KV high voltage insulation test;

        ● Full digital control technology, so that the whole machine control is accurate, fast, reliable and stable;

        ● Twelve pulses or active filter to effectively correct the input power factor and prevent the UPS to pollute the power grid;

        ● Powerful intelligent monitoring function, can provide RS232, RS485, dry contact point and parallel machine interface;

        UPS power supply environment monitoring system, with the international leading technology level, has developed intelligent single and network integration real-time monitoring management software, providing users with professional, perfect, practical, safe and reliable power monitoring scheme, so that intelligent network quickly and reliably manage UPS system. UPS centralized monitoring and management software can monitor UPS worldwide, integrating point-to-point to-point, point-to-many, multi-to-point, many-to-many full-function network topology structure, forming a huge intelligent UPS power network monitoring and management system.

        Features of the real-time monitoring software:

        1. Real-time monitoring for single users;

        2. Real-time monitoring for the centralized management of large-scale WAN.

        ● Flexible networking scheme

        RS232, RS485, dry contact, SNMP card, Modem can meet TCP / IP protocol and adapt to LAN, WAN and INTERNET network monitoring.

        1. The RS232 serial communication interface is connected one to one, which is directly connected with the RS232 communication port of the computer, realizing the two-way data exchange, remote monitoring and intelligent management in close distance (<100m) between the computer and UPS equipment.

        2. RS485 adopts advanced balance circuit, improved interface RS485 serial communication standard, duplex communication mode, one-to-one connection. Dedicated RS485 / RS232 interface converter is connected to the communication interface of RS232 of the computer and connected to the computer through a cable to support data transmission at high speed and distance (<1200mm).

        3, SNMP network card adopts the world's popular Ethernet technology, advanced TCP / IP network protocol, duplex communication mode, many-to-many connection. UPS built-in or external dedicated SNMP network card connects with computer-configured network card to realize intelligent monitoring of<100m; it is also connect to the LAN to implement networked monitoring of one (or multiple) UPS.

        4. UPS built-in Modem can dial through the telephone line to the local telephone network, call the landline, mobile phone, prompt the UPS abnormal state: bypass, shutdown, battery low voltage, overload, etc.

        5. The UPS dry contact alarm signal conducts long-distance alarm through the contact closure, connects the remote indicator light, electric bell and relay execution unit, prompting no city power, battery low voltage, machine fault, etc.


        Technical Specifications


        (I) Rectifier input and output parameters

        1.Rectifier input parameters

        Model

        10kVA

        20kVA

        30kVA

        40kVA

        60kVA

        80kVA

        100kVA

        120kVA

        160kVA

        200kVA

        250kVA

        300kVA

        400kVA

        500kVA

        600kVA

        Nominal capacity (kW)

        8

        16

        24

        32

        48

        64

        80

        96

        128

        160

        200

        240

        320

        400

        480

        Single-phase maximum input

        19

        38

        57

        76

        114

        152

        190

        228

        304

        379

        475

        570

        760

        950

        1140

        current (A)

        Working mode and principle

        Online ??power supply, static bypass switch (no intermittent switching), dual ??conversion technology, the output power supply is

        completely ??isolated

        Input power factor

        0.8/0.9(12 pulses)/0.95(with ????active filter)

        Number of phases

        Three-phase+N+G

        Nominal voltage

        380VAC±25%

        Nominal frequency

        50/60Hz±10%

        Input current harmonics

        <5%

        Soft start

        0~100%5sec

        2.rectifier output ?parameters

        Model

        10kVA

        20kVA

        30kVA

        40kVA

        60kVA

        80kVA

        100kVA

        120kVA

        160kVA

        200kVA

        250kVA

        300kVA

        400kVA

        500kVA

        600kVA

        Maximum output voltage (VDC)

        432V

        648V

        The microcomputer sets the

        6~30A(adjustable)

        charging current

        (2) Battery

        Model

        10kVA

        20kVA

        30kVA

        40kVA

        60kVA

        80kVA

        100kVA

        120kVA

        160kVA

        200kVA

        250kVA

        300kVA

        400kVA

        500kVA

        600kVA

        Maximum discharge current (A)

        28

        56

        85

        113

        169

        225

        282

        338

        461

        576

        700

        840

        1120

        1400

        1120

        Number of batteries per group

        12V32pcs or 2V192pcs

        12V48pcs

        Nominal battery voltage

        384VDC

        576VDC

        Floating charge voltage

        432VDC

        648VDC

        Charging current

        6~30A(adjustable)

        (3) Inverter

        Model

        10kVA

        20kVA

        30kVA

        40kVA

        60kVA

        80kVA

        100kVA

        120kVA

        160kVA

        200kVA

        250kVA

        300kVA

        400kVA

        500kVA

        600kVA

        Power rating (kW)

        8

        16

        24

        32

        48

        64

        80

        96

        128

        160

        200

        240

        320

        400

        480

        Number of phases

        Single-phase or three-phase+N+G

        three-phase+N+G

        Nominal voltage

        220/380VAC±1% (steady state)

        380VAC±1% (steady state)

        Nominal frequency

        50/60Hz±0.5% (battery mode)

        Output power factor

        0.8/0.9

        Frequency stability

        <±0.5% (when out of ????synchronization)

        <±2% (when synchronized ????with mains)

        Crest factor

        3:1

        Discharge waveform

        sinusoidal wave

        Total harmonic distortion

        Linear ??load<3%; ??nonlinear load <5%

        Dynamic load voltage transient

        <4%

        Moment recovery time

        <10ms

        Balanced load voltage

        <± 1%;<5% (unbalanced ??negative hub)

        Overload capacity

        125%30min,150%1min,>150%300ms

        Inverter efficiency (load of?100%)

        >93%

        >96%

        (4) Bypass

        Model

        10kVA

        20kVA

        30kVA

        40kVA

        60kVA

        80kVA

        100kVA

        120kVA

        160kVA

        200kVA

        250kVA

        300kVA

        400kVA

        500kVA

        600kVA

        Number of phases

        Single-phase or three-phase+N+G

        Three-phase+N+G

        Nominal voltage

        380VAC±15%

        Nominal frequency

        50/60Hz±10%

        Transfer time

        0ms

        (5) System

        Model

        10kVA

        20kVA

        30kVA

        40kVA

        60kVA

        80kVA

        100kVA

        120kVA

        160kVA

        200kVA

        250kVA

        300kVA

        400kVA

        500kVA

        600kVA

        Computer communication

        interface

        RS232, RS485, dry contact, smart ??slot

        Running temperature

        0~40

        Relative humidity

        0%~90% ?(no condensation)

        Operating height(max.)

        <1000m (1% for 100m, maximum ??4000m)

        Cooling-down method

        Forced draft

        Noise

        48~65dB

        53~68dB

        60~75dB

        MTBF

        300000 Hours

        Levels of protection

        IP20

        Box color

        Black(optional white)

        Input cord

        Bottom/back

        Easy to maintain

        Front/ top/side

        Outline dimension (mm)

        D

        685

        760

        800

        880

        1050

        W

        360

        360

        660

        900

        1550/2250(12 pulses)

        H

        825

        990

        1550

        1650

        1900

        Reference Weight (kg)

        128

        175

        230

        280

        380

        550

        650

        700

        850

        900

        1050

        1500

        1700

        1900

        2300

        Input equipment

        Terminal row

        Output equipment

        Terminal row

        Note: Customizable output power PF=0.9.

        * The above parameters may be adjusted and changed, please refer to the physical object