        D series high-frequency online UPS 6~20kVA

        Product profile

        Digital Series (parallel redundancy) UPS D6KS ~ 3 D 20 KS with double conversion pure online architecture, the architecture can block the impact of abnormal power on the load, at the same time also can guarantee the stable and reliable output, let the safety of the load, is the best can effectively solve the problem of all power architecture design, using digital control technology (DSP / MCU chip), can choose the function of parallel expansion and parallel redundancy, provide the user with power planning elasticity and more secure guarantee.


        Basic Features

        Smaller design

        The application of advanced control technology, greatly improve the power factor, small volume, light weight.


        Online maintenance design (optional)

        If you select the maintenance switch, you can safely carry out online maintenance under the condition of continuous load power supply as long as you turn the UPS to the maintenance mode; If you plan for N+1 parallel redundancy, even if the mains power is interrupted during maintenance, your valuable equipment can get uninterrupted high-quality power supply.


        Comprehensive functional design

        DC start function enables you to use UPS without mains power supply. The function of timing on/off and remote monitoring can realize the goal of unmanned. The powerful charging function is convenient for you to extend the standby time. The intelligent charging mode extends the battery life and saves

        money. The automatic restart function makes it unnecessary for you to turn on the UPS in person after the standby UPS is turned off. Comprehensive functional design brings more convenience to your work.


        Excellent technical indicators

        The input power factor close to 1 greatly reduces the pollution to the municipal power grid, improves the utilization of the grid, and is a real green power source. The ultra wide input voltage range provides the most complete protection for your valuable equipment under various harsh power environments.

        Nearly 93% full load operation efficiency, effectively saving your electricity bill. Strong anti-interference ability, meeting the requirements of IEC61000-4 for electromagnetic interference, can effectively eliminate noise, high voltage and breakthrough on the power grid, and provide a clean power environment for your

        equipment.

        image.png


        Optional lightning protection function

        It can be equipped with Class D lightning arrester with surge and lightning protection design to effectively protect equipment from lightning interference.


        High-reliability and parallel capacity expansion technology (optional)

        You only need to consider your actual power needs and plan an appropriate UPS. In the future, if you need corresponding power expansion due to equipment expansion, you only need to purchase the expanded UPS and connect it to the original power system in parallel, which increases the flexibility of planning and greatly reduces the waste of investment.?


        N + X parallel redundancy function (optional)

        The N+X parallel redundancy function means that there is one more UPS at any time to guarantee your important equipment. When planning the power supply system, add one more than the rated capacity. In this way, when any UPS in the system fails, the additional UPS will enable the power supply system to continuously provide high-quality power for your important equipment, making the system more reliable. At the same time, the advanced current sharing technology enables each UPS in parallel operation to share the load current equally. While improving the system reliability, It also extends the service life of UPS.


        Intelligent power supply monitoring and management software: UPSILON 2000

        Support Microsoft Windows95/98/Me/NT/2000/XP/Linux operating system, applicable to TCP/IP LAN, and support TCP/IP network monitoring UPS; Provide hierarchical directory structure management network UPS; Abnormal event notification; Automatically detect UPS model and communication port; Provide password protection; UPS can be switched on/off regularly; Support UPS timing self-test function; Support graphic real-time display of UPS status; Support network shutdown of servers and workstations; Support closing most applications and saving related documents; Support multi language and English platforms; Support online help function. It has the function of data recording (including mains power, UPS, load, battery) and event log, which is convenient for the system administrator to carry out daily UPS maintenance.?


        Complete monitoring and communication function?

        RS-232, intelligent slot (Intelligent Slot) and other monitoring and communication interfaces are provided. Users can realize centralized monitoring and remote monitoring functions through the SNMP network card.


        Technical Specifications

        ? ? ?? ? ? ? ? Model

        D6K

        D6KS

        D10K

        D10KS

        3D10KS

        3D15KS

        3D20KS

        Rated capacity (PF=0.9)

        6kVA/5.4kW

        10kVA/9kW

        15kVA/13.5kW

        20kVA/18kW

        Input

        Input distribution line

        Single-phase second-line+ground line

        Three-phase, four-wire+ground wire

        Voltage

        120VAC~300VAC

        150VAC~500VAC

        Frequency

        50/60Hz±10%

        Output

        Voltage

        220/230±1%VAC

        Frequency

        Synchronizing with the input (mains mode)

        50/60Hz±0.5% (battery mode)

        Load peak?

        ratio

        3:1?(max)

        Discharge waveform

        Pure sine wave

        Transfer time

        Zero interruption

        Built-in battery (12V)

        7Ah/9Ah×16

        -

        7Ah/9Ah×16

        -

        -

        External battery DC voltage nominal

        -

        192Vdc

        -

        192Vdc

        192/240Vdc

        Battery type

        Valve-controlled lead-acid maintenance-free storage battery

        Overload capacity

        105% -120%, to?bypass?after?10 seconds;
        120-140%,?to?bypass?after?200ms;
        ? ?140-150%,?to?bypass?after?200ms, and then?shutdown?10 seconds later;
        ? > 150% shutdown?immediately

        Distortion rate (full load)

        <3% (linear load)

        <5% (nonlinear load)

        Communication function

        Rs-232 interface (optional USB interface)+SNMP smart slot

        Working temperature

        0℃~40℃

        Relative humidity

        0~90% (no condensation)

        Dimension(D×W×H) mm

        515×248×616

        515×240×460

        515×248×616

        515×240x460

        540×190x340

        560×240×530

        Weight (kg)

        57/64

        17.5

        60/67

        19.5

        15.5

        28.5

        28.5

        Compliancewithstandards

        ?GB/T14715-2017; YD/T1095-2018; EN62040-1:2008+A1:2013; EN62040-2:2018

        1. Optional rated capacity (output power) PF = 0.8.

        2. The model with "S" is a extended time model, and the battery should be configured according to the external battery DC voltage according to the battery life time.

        3. Load in high altitude = rated power x reduction coefficient

        Altitude (m)

        1000

        1500

        2000

        2500

        3000

        3500

        4000

        4500

        5000

        Frequency reduction coefficient

        100%

        95%

        91%

        86%

        82%

        78%

        74%

        70%

        67%

        ?If the UPS is used above 1000m, the decreasing rated output must be used, as shown in the table above.

        * The above parameters may be adjusted and changed, please refer to the physical object.