        Integrated power supply and distribution UPS (PDM15-180kVA)

        Product profile

        The company's second generation PDM series integrated UPS power supply adopts full modular design, power module 15 / 20 / 25 / 30 kVA optional, capacity covering each power segment between 15 kVA and 180 kVA, convenient for users to flexible configuration and gradual investment. Power distribution is flexible and optional, with direct load. The product integrates modular UPS, precision power distribution, intelligent monitoring three systems, the machine room power one cabinet to solve. It can fully eliminate the impact of various power grid problems on key loads, has the characteristics of reliable, efficient, intelligent, flexible and simple maintenance, and can provide ideal power supply protection for customers in medium-sized power supply scenarios. Products are highly integrated, with cost saving, space saving, simplified installation and debugging and operation and maintenance management.



        Basic Features

        Application area

        Small and medium-sized data center, IT computer room, financial institutions, traffic dispatch center, security monitoring, etc.


        Features and advantages

        1. Set power cabinet, modular UPS, output cabinet and intelligent monitoring four functions to realize the integration of multiple cabinets and save space.

        2. 10.1 inch color touch control screen, built-in Chinese / English one-button switching function interface, for UPS, power distribution operation control, operation status view, parameter setting, alarm view and other functions. Easy to quickly view the current device status, and can touch the local control.

        3. Strong access ability, can flexibly expand the moving ring monitoring function. Support intelligent equipment and DI dry contact input equipment connected by RS485 and TCP communication mode, can expand the room access control management, temperature and humidity, fire protection, battery management, precision air conditioning monitoring, SMS alarm and other functions, to achieve multi-effect integration.

        4. Built-in web service, which can be remotely monitored and managed through the browser and APP.

        5. Support custom alarm configuration, alarm support SMS notification (optional 4G version) and email push (need to be connected to the external network).

        6. The data can be uploaded to the centralized management platform through the northbound interface, and the local data can be exported to the U disk.

        7. large capacity storage, with 4G storage capacity, can be expanded through TF card, the maximum support of 128G, historical data can be stored for 1 year, offline real-time storage for 7 days.

        8. Ultra-wide input voltage range of 138 V ~ 485 Vac, 305 ~ 485 Vac, 138 ~ 305 Vac linear decrease, adapted to the harsh power grid.

        9. Full modular design of power module, bypass module and control module.

        10. Each module supports hot plug, which is convenient for users to flexibly configure and invest gradually in, and easy to maintain.

        11. The mains input mode is optional. Dual input is standard equipped with PC class ATS with fire control function, which has fast switching response and ensures the continuity and safety of power supply.

        12. UPS can share the battery pack, and the number of external battery pack segments 30-50 is flexible and adjustable.


        Product mix


        image.png




        Technical Specifications

        Product model

        MP-90K-PDM - MCCB160

        MP-90K-PDM - ATS160

        MP-120K-PDM - MCCB250

        MP-120K-PDM - ATS250

        MP-150K-PDM - MCCB400

        MP-150K-PDM - ATS400

        MP-180K-PDM - MCCB630

        MP-180K-PDM - ATS630

        Total output capacity of the cabinet

        105kVA

        150kVA

        250kVA

        400kVA

        UPS

        UPS frame capacity

        90kVA/90kW

        120kVA/120kW

        150kVA/150kW

        180kVA/180kW

        Adaptation module specifications

        15 / 20 / 25 / 30 kVA (kW) height: 2U

        Maximum number of modules

        3

        4

        5

        6

        Import

        Enter the system

        Three-phase, four-wire + PE

        Rated input voltage

        380 Vac / 400 Vac / 415 Vac (line voltage)

        Input voltage range

        138 to 485 Vac; 305 to 485 Vac, 138 to 305 Vac.

        Input frequency range

        40Hz 70Hz

        Input power factor

        > 0.99

        Input current harmonic component

        THDi 3% (linear load, highest point reached); THDi 5% (non-linear load, highest point reached).

        Bypass

        Rated AC voltage

        380 Vac / 400 Vac / 415 Vac three-phase four-wire, common mid-line with the rectifier input, to provide a mid-line reference for the output.

        Overload

        <110%, 1="" 5="" long-term="">150%, 1 second.

        Rated midline current

        1.7 ×In

        Frequency

        50/60Hz

        Switching period

        ≤2mS

        Bypass voltage range

        Can be set: upper limit: + 5%, + 10%, + 15%, + 20%, + 25%, default is + 15%; lower limit: -20%, -30%, -45%, default is-20%.

        Output

        Output system

        Three-phase four wire + PE (midline with bypass)

        Rated output voltage

        220 Vac / 230 Vac / 240 Vac (phase voltage)

        Stable pressure accuracy

        ± 1% (balanced load)

        Rated output frequency

        50/60Hz

        Output power factor

        1

        Output voltage imbalance degree

        ± 1% (0 to 100% Linear load)

        Inverse overload capacity

        100%<110% load, bypass after 60min; 110% <125% load, 10min bypass; 125% <150% load, 1min bypass; 200ms after 150% and short circuit.

        Emergency Shutdown (EPO)

        Close the output immediately

        Cell

        Supporting battery type

        Standard: Valve-acid battery (VRLA) (optional lithium battery)

        Battery voltage

        ±180 ~ ±300Vdc

        Number of battery parallel groups

        Group 1 ~8

        Battery section number

        30 ~50 (12V battery, default 12V battery 40, battery number double number adjustment)

        Floating charge voltage

        2.25V / cell (with a range: 2.20V / cell ~2.30V / cell)

        Temperature compensation

        -3.0 mV / Cell / ?(range: 0- -5.0)

        Generalized voltage

        2.35V / cell (available range: 2.30V / cell ~2.40V / cell)

        Final discharging voltage

        1.80V / cell (available range: 1.60V / cell ~1.90V / cell)

        Maximum charging current

        Range: (1 ~15A) * number of modules

        Distributing

        Input mode

        Single-way three-phase four-wire + PE

        Double-road, three-phase and four-wire + PE

        Single-way three-phase four-wire + PE

        Double-road, three-phase and four-wire + PE

        Single-way three-phase four-wire + PE

        Double-road, three-phase and four-wire + PE

        Single-way three-phase four-wire + PE

        Double-road, three-phase and four-wire + PE

        Input specification

        MCCB160A/3P

        PC grade ATS160A / 4P

        MCCB250A/3P

        PC grade ATS250A / 4P

        MCCB400A/3P

        PC grade ATS400A / 4P

        MCCB630A/3P

        PC grade ATS630A / 4P

        UPS distributing

        Input, bypass, output, maintenance bypass: 100A / 3P * 4, MCCB

        Input, bypass, output, maintenance bypass: 160A / 3P * 4, MCCB

        Input, bypass, output, maintenance bypass: 250A / 3P * 4, MCCB

        Input, output and maintenance bypass: 250A / 3P * 3, MCCB

        Live load

        Air conditioning: 63A / 3P / 4, mains: 10A / 1P / 3.

        IT load

        (32A / 1P * 15 + 63A / 1P * 3) * 2 road, MCB

        (32A / 1P * 21 + 63A / 1P * 3) * 2 road, MCB

        (32A / 1P * 21 + 63A / 1P * 3) * 2 road, MCB

        (40A / 1P * 18 + 63A / 1P * 6) * 2 road, MCB

        Lightning protection

        Class C lightning protection, 20 kA / 4P.

        Supervisory control

        Standard configuration

        Full power parameters and switch status monitoring of main / branch distribution; Monitoring of complete UPS operating parameters and operating parameters of each module unit; Browser Remote access monitoring system, Remote viewing, setting, and control (connected to the external network); Email and wechat alarm, Mobile APP remote monitoring management (connected to external network); Support for the Modbus TCP / SNMP northbound interface; The monitoring content also includes: equipment real-time status query, alarm query, historical data query, system log query, alarm event management, alarm notification mode, user alarm Settings, alarm notification record, alarm linkage record, equipment management, user management, system Settings and other functions;

        Apolegamy

        Air conditioning monitoring, battery management, access control management, local sound and optical alarm, SMS alarm or telephone SMS two-in-one alarm, environmental temperature and humidity monitoring, water leakage detection, smoke detection, rack embedded fire extinguisher, etc.

        System

        System effectiveness

        > 95.5%

        Levels of protection

        IP20

        Communication interface

        Dry contacts, RS485, and SNMP

        Running temperature

        040

        Storage temperature

        -25 70

        Relative humidity

        5 ~ 95% RH (no condensation)

        Above sea level

        0 ~1000m (IEC62040-3 standard above 1000m, up to 4000m)

        Physical characteristics

        Reference weight

        327kg

        332kg

        356kg

        363kg

        397kg

        407kg

        422kg

        430kg

        Dimensions (W * D * H)

        600*1100*2000mm/600*1200*2000mm

        Operative norm

        CE ,EN/IEC 62040-2 ,EN/IEC 62040-1-1 ,YD/T 2165-2017